ATA COMMAND BLOCK AND SET DESCRIPTION SSD-PXXX(I)-3100 DATA SHEET
SILICONSYSTEMS PROPRIETARY
This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.
All unauthorized use and/or reproduction is prohibited.
3100P-06DSR PAGE 92 FEBRUARY 2, 2009
Wear-Level — F5h
The Wear-Level command is supported as an NOP command for the
purposes of backward compatibility with the ANSI AT attachment standard.
This command sets the Sector Count register to 0x00h.
Table 79: Wear-Level — F5h
Register
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Feature X
Sector Count Completion Status
Sector Number X
Cylinder Low X
Cylinder High X
Drive Head X X X Drive Flag
Command F5h